High Visibility TDR Probe with fixed 0.100" ground spacing
TDR Probe A0131990 -- For UTP-3000 Series and other Fixtures


Features

Narrow Body design for High Visibility

Fixed 0.100" Ground Spacing

Ground Contact Assy. A0131806 (1 ground
    contact)

Ground Contact Assy. A0131721 (2 ground/span>
    contacts)

SMA Connector

Spring Loaded Ground Pin with extra travel

Fixed RF Pin

Optional Calibration Adapter Kit A0130860 for
    TDR Oscilloscope Calibration

Application Note on TDR Oscilloscope Calibration

Microstrip Calibration Kit ICM P/N: A0131444
    (DC - 1 GHz)



The design features a SMA Connector with a 50 Ohm
transition section for use up to 6 GHz. The Ground Contact
is made by a Spring Loaded Contact to ensure good ground
contact. Different Ground Spacing Assemblies can be
purchased for custom spacing requirements.
The TDR Probe can be used by hand or with the help of an
external fixture such as the UTP-3000 Series or the
Adjustable Probe Holder Assembly. (Both require the Split
Clamp Assembly (ICM P/N A0113937) for 0.250" Dia.
Probes.)

The ICM TDR Probe offers a good, low cost, easy to use
solution to testing TDR in a variety of circumstances








Optional Ground Contact Assemblies with 2
Ground Pins are available.(A0131721)




TDR Probe with optional Calibration
Adapter Kit A0130860 for Open, Short, and
Load Calibration with TDR Oscilloscopes



High Visibility TDR Probe with movable ground in 0.02" increments (0.06" to 0.20")
TDR Probe A0131668 -- For UTP-3000 Series and other Fixtures

Features

Narrow body design for High Visibility

Movable Ground Contact from 0.06" to 0.20" in
    0.020" increments

SMA Connector

Spring Loaded Ground Pin

Optional Calibration Adapter Kit A0131991 for
    TDR Oscilloscopes

Application Note on TDR Oscilloscope Calibration

Microstrip TOSL Calibration Kit ICM P/N:
    A0131444 (DC - 1 GHz)

Instructions on Ground Pogo Pins -- PDF Format


Specifications:
Frequency Range: DC - 6 GHz
Insertion Loss: < 1 dB
Return Loss: > 16 dB



The design features a SMA Connector with a 50 Ohm
transition section for use up to 6 GHz. The Ground Contact
is spring loaded to accommodate tolerance differences
between the height of the RF and Ground Contact points. It
is also removable so that you can position it in the different
holes to allow for different RF to Ground pitch distances.
These distances are set at 0.020" increments, so most points
between 0.06" and 0.20" can be met.
The TDR Probe can be used by hand or with the help of an
external fixture such as the UTP-3000 Series or the
Adjustable Probe Holder Assembly. (Both require the Split
Clamp Assembly (ICM P/N A0113937) for 0.250" Dia.
Probes.)

The ICM TDR Probe offers a good, low cost, easy to use
solution to testing TDR in a variety of circumstances.








Probe with optional Calibration Adapter Kit
installed.




Calibration Adapter Kit partially installed.


TDR Probe with adjustable ground spacing from 0.13" to 1.0" TDR Probe with movable ground in 0.01"


 